Goldline Aqualogic No Cell Power 2

Chlorinator Off No Cell Power Diy Repair Youtube

Chlorinator Off No Cell Power Diy Repair Youtube

Aqua Plus Check System No Cell Power 2 Trouble Free Pool

Aqua Plus Check System No Cell Power 2 Trouble Free Pool

Repair Your Hayward Goldline Aqua Logic Glx Pcb Main System Board For Sale Online

Repair Your Hayward Goldline Aqua Logic Glx Pcb Main System Board For Sale Online

Pro Logic Version Diagnostics Manual Pdf Free Download

Pro Logic Version Diagnostics Manual Pdf Free Download

Goldline Controls Pcb Circuit Board Aqualogic Glxpcbmain Inyopools Com

Goldline Controls Pcb Circuit Board Aqualogic Glxpcbmain Inyopools Com

Http Www Haywardnet Com Pdfs Prologic 4 45 Troubleshooting Guide Pdf

Http Www Haywardnet Com Pdfs Prologic 4 45 Troubleshooting Guide Pdf

Http Www Haywardnet Com Pdfs Prologic 4 45 Troubleshooting Guide Pdf

Main pcb layout a i remote dsp comm rs485 10vdc b temp sensor terminal block 5vdc c heater 1 2 terminal block dry contacts d valves 1 4 4amp fuse 24vac e cell plug for chlorination f high voltage relays top filter lights aux1 aux2.

Goldline aqualogic no cell power 2.

G flow monitor flow switch connector h p transformer input 120vac x 2. Almost all goldline controls replacement parts have a date code. Please contact tech service. Turn on the main braker and your goldline.

My display is saying chlorinator off no cell power and check system no cell power 2. Unplug the yellow fuse from its socket. If i re boot it will display correctly for about a minute and then you can feel the cylenoid looking thing clicking and then it will display as mentioned above. Turn off the main braker unplug the yellow and orange cable above the yellow fuse top right.

In diagnostic mode it shows 0v 0a in both positive and negative polarity so something is definitely wrong. No low voltage detected when the cell power was turned on. If the voltage is ok go to step 1c. Same with the serial numbers on your cells and control boxes after the 5a 5e 5l 3l and 3e.

If you get no cell power before doing anything else here s the easiest testing method. Replace main board pcb. This must be resolved by a certified technician. Verify that 20 24 volts ac is present between the two yellow wires.

No cell power 1 or no cell power 2 no cell power 1 no cell power 2 go to step 1a page 4. Try starting the filter pump. If no voltage is measured continue to step 1b. 908 355 7995 or contact a pool professional.

Plug both wire to the fuse directly. Goldline controls warrantied these flow switches if they failed in the field and were of the specified lot. Please add liquid chlorine to the pool until the issue has been resolved. I called goldline and they said it is probably the main board.

Goldline Aqua Logic Check System Low Salt Error Trouble Free Pool

Goldline Aqua Logic Check System Low Salt Error Trouble Free Pool

Goldline Aqualogic Owners Manual

Goldline Aqualogic Owners Manual

Goldline Aqua Plus No Cell Power Trouble Free Pool

Goldline Aqua Plus No Cell Power Trouble Free Pool

Hayward Goldline Aqua Logic Glx Pcb Main Circuit Board Pool Supply 4 Less

Hayward Goldline Aqua Logic Glx Pcb Main Circuit Board Pool Supply 4 Less